# Cooling Patrol: Screen and Screenshot Inventory

> Editorial inventory of Cooling Patrol screens, available captures, and technical details pending confirmation.

This page is the working inventory for illustrating the Cooling Patrol documentation. It links only public resources that have already been checked; pending captures must be taken in a demo building or with anonymized data before publication.

## Inventory

| Screen or resource               | App path or entry point                | What it should show                                                                                                                          | Status                                                                                                    |
| -------------------------------- | -------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------- | --------------------------------------------------------------------------------------------------------- |
| Hub Wi-Fi connection             | Connection assistant                   | Selecting the Hub network and joining the site's Wi-Fi.                                                                                      | **Available:** [UI WiFi connect](https://cdn.voltic.es/media/cooling-patrol/product/ui_wifi_connect.webp) |
| Sensor identification            | QR onboarding/label                    | Cooling Patrol name, QR code, and serial number with customer data removed.                                                                  | **Capture pending**                                                                                       |
| Cooling Patrol overview          | `Cooling Patrol > Overview`            | Room count, Online/Offline, active alerts, average temperature, compliance, trend, and recent alerts.                                        | **Capture pending**                                                                                       |
| Hub offline and data loss        | Overview warning                       | Gateway/Hub offline warning, last reading received, and **No data** state for affected sensors.                                              | **Capture pending**                                                                                       |
| One-room status                  | Overview sensor list                   | Search, All/Online/Alerts/Offline filters, state, range, battery, and last update.                                                           | **Capture pending**                                                                                       |
| Sensor details                   | Select a room                          | Current temperature, allowed range, status, battery, voltage, history, humidity/signal when available, Hub, location, and anonymized serial. | **Capture pending**                                                                                       |
| CoolingPatrol Alerts: individual | Building view > `CoolingPatrol Alerts` | Enabled state, minimum, maximum, and saving one alert.                                                                                       | **Capture pending**                                                                                       |
| CoolingPatrol Alerts: advanced   | `Advanced alert settings`              | Hysteresis, cooldown, and breach duration.                                                                                                   | **Capture pending**                                                                                       |
| CoolingPatrol Alerts: bulk       | Select several sensors                 | Replacing the complete configuration and per-sensor results.                                                                                 | **Capture pending**                                                                                       |
| HACCP: Register                  | `HACCP > Register`                     | Status/date filters, search, start, excursion, duration, status, and table export.                                                           | **Capture pending**                                                                                       |
| HACCP: Alerts                    | `HACCP > Alerts`                       | Each alert's state, sensor, location, and configuration entry point.                                                                         | **Capture pending**                                                                                       |
| HACCP: Reports                   | `HACCP > Reports`                      | Period, date, per-sensor chart option, summary, and `Download PDF` button.                                                                   | **Capture pending**                                                                                       |
| Incident details                 | Open an HACCP record                   | Start, recovery, limit, peak, cause, corrective action, product/lot, disposition, responsible person, and review/lock.                       | **Capture pending**                                                                                       |
| PDF report                       | `Download PDF`                         | Self-control document with period, time zone, per-sensor control, and deviations.                                                            | **Anonymized sample pending**                                                                             |

The [front\_nb.png sensor image](https://cdn.voltic.es/media/cooling-patrol/product/front_nb.png) is a product resource, not an app screenshot. It can identify the device while interface captures are pending.

## Capture criteria

* Use a demo building and demo sensors; remove customer names, addresses, serial numbers, email addresses, and personal data.
* Capture the normal state and, where possible, controlled examples of **Out of range**, **No data**, and **Offline** without changing a real installation.
* Keep the visible time zone, °C units, and exact control labels.
* Provide WebP or PNG images with the same crop and resolution for Spanish and English.
* Store the app version, user role, date, and publication permission with each image.

## Technical confirmations before publication

| Detail                                                                                             | Why it needs confirmation                                                                                                   |
| -------------------------------------------------------------------------------------------------- | --------------------------------------------------------------------------------------------------------------------------- |
| Default values and maximum/minimum ranges for threshold, hysteresis, cooldown, and breach duration | The app shows the fields, but valid ranges and initial values may depend on version and stored product.                     |
| Notification channels, recipients, repetition, and escalation                                      | The observed interface configures the alert, but it does not document here how notifications are sent or who receives them. |
| Reading cadence, timeout before **No data**, and reconnection behavior                             | This determines when a reading is no longer usable and what must be measured manually.                                      |
| Hub startup time and the 30–60 minute wait after onboarding                                        | These operational times appear in the installation guide and must be validated for the deployed hardware and firmware.      |
| Sensor/battery type, capacity, life, polarity, replacement, and protection rating                  | These are not defined in this documentation and must not be inferred from other Voltic sensors.                             |
| Placement point, tolerance, interval, and calibration method; offset support                       | These metrology and installation requirements must come from the model manual and site procedure.                           |
| Definition of **Critical** versus **Warning**                                                      | The app shows both labels, but the operational criterion must match the HACCP plan.                                         |
| Retention period, signature/lock, accepted format, backups, and reviewing authority                | The app offers states and exports, but official-record validity depends on jurisdiction and the applicable procedure.       |
| Permission matrix for managing alerts, resolving, and reviewing incidents                          | Visible controls change by role; validate who can perform each action.                                                      |

### Values observed in the interface (do not publish yet)

The current app validation shows the following limits and initial values. They are implementation references, not an approved specification:

| Field                     | Observed                                                              | Confirmation pending                                                             |
| ------------------------- | --------------------------------------------------------------------- | -------------------------------------------------------------------------------- |
| Alert enabled             | A new form appears enabled.                                           | Onboarding policy for already-installed sensors.                                 |
| Minimum/maximum threshold | Inputs between −100 and 100 °C; maximum must be greater than minimum. | Product operating range and whether it matches the visual control.               |
| Visual allowed range      | The range slider shows −20 to 20 °C.                                  | Resolve the difference with the −100 to 100 °C validation before documenting it. |
| Hysteresis                | 0–50 °C; observed initial value: 0 °C.                                | Operational meaning and recommended value per installation.                      |
| Wait between alerts       | 1–10,080 min; observed initial value: 60 min.                         | Minimum, maximum, and repetition policy.                                         |
| Duration before incident  | 0–1,440 min; observed initial value: 5 min.                           | Whether 0 is allowed for every model and when the record is created.             |

<Warning>
  Until these points are closed, describe controls as **available in the observed interface**, not as requirements, defaults, or a compliance guarantee.
</Warning>

## Related links

* [Operation, alerts, and history](/en/cooling-patrol/operation)
* [Installation guide](/en/cooling-patrol/installation)
* [Contact support](/en/support/contact)


## Related topics

- [Cooling Patrol: Cold Room Temperature Monitoring](/en/cooling-patrol/index.md)
- [Cooling Patrol: Operation, Alerts, and History](/en/cooling-patrol/operation.md)
- [Cooling Patrol: Step-by-Step Installation Guide](/en/cooling-patrol/installation.md)